Changing a Run-time Parameter

To modify the run-time environment:

  1. Copy the macro module GTM$DEFAULTS.MAR from GTM$DIST.

                  $ Copy GTM$DIST:GTM$DEFAULTS.M64 []
                
  2. Edit 'GTM$DEFAULTS.M64 to modify the parameters controlling the desired factors.

                  $ Edit GTM$DEFAULTS.M64
                

    Example:

            GTM$DEFAULTS
            GTM$USER_STACK_SIZE == 16384
            GTM$USER_INDRCACHE_SIZE == 128
            GTM$USER_STRPL_SIZE == 20480
            GTM$USER_IO_TIMER == 3300000
            GTM$USER_WRITE_FILTER == 0
            GTM$SPECIAL_INPUT == ^X00200000
            GTM$UNDEF_INHIBIT == 0
            GTM$CTRLC_ENABLE == 1
            GTM$BREAK_MESSAGE_MASK == 15
            GTM$LOWER_CASE_LABELS == 1
            GTM$LVNULLSUBS == 1
            GTM$ZDIR$FORM == 0
            GTM$ZDATE$FORM == 0
                

    This enables the alternative handling of (SPECIAL_INPUT) <CTRL-U>.

    [Note]

    GTM$DEFAULTS must have values for all parameters and all parameter names must be spelled correctly.

  3. Assemble (MACRO) GTM$DEFAULTS.M64 to produce GTM$DEFAULTS.OBJ.

            $ Macro/migrate GTM$DEFAULTS 
            $ Macro/alpha_axp GTM$DEFAULTS
                
  4. LINK one or more images that include the revised GTM$DEFAULTS.OBJ.

                  $ Link image_name.obj,GTM$DEFAULTS
                

    When linking the GT.M executable image, include GTM$DEFAULTS.